Numéro
J. Phys. II France
Volume 6, Numéro 7, July 1996
Page(s) 969 - 984
DOI https://doi.org/10.1051/jp2:1996111
DOI: 10.1051/jp2:1996111
J. Phys. II France 6 (1996) 969-984

Shear-Induced Deformation and Desorption of Grafted Polymer Layers

M. Aubouy1, 2, 3, J.L Harden3, 4 and M.E. Cates3

1  Laboratoire de Physique de la Matière Condensée URA n° 792 CNRS, Collège de France, 11 place Marcelin Berthelot, 75231 Paris Cedex 05, France
2  Laboratoire de Reconnaissance des Matériaux dans leur Environnement UPR n° 343 CNRS, Université de Marne-la-Vallée, 2 rue du Promontoire, 93166 Noisy-le-Grand Cedex, France
3  Department of Physics and Astronomy, University of Edinburg, James Clerk Maxwell Building, King's Building, Mayfield Road, Edinburgh EH9 3JZ, UK
4  Cavendish Laboratory, Cambridge University, Madingley Road, Cambridge CB3 OHE, UK

(Received 29 December 1995, received in final form 1 April 1996, accepted 4 April 1996)

Abstract
We describe the behaviour of grafted polymer layers in strong solvent shear flows within a model where only a subset of chains are exposed to the flow (hence to the tension arising from hydrodynamic drag forces), leaving the remainder protected. We show that for quite small values of the shear rate, $\dot\gamma$, the system reaches a self-regulating state where the lowest possible fraction of grafted chains is exposed to the flow. This brings quantitative corrections to previous models (all based on the assumption that the chains behave alike) which correspond to a higher susceptibility of the layer to shear fields: the onset of significant swelling occurs at a lower shear rate and at high shear rates the asymptotic value of the relative swelling is somewhat larger. Furthermore we find that the behaviour of the layer strongly depends on both the index of polymerisation of the chains and the grafting density. In particular, for thick brushes, our model predicts a discontinuous (first order) swelling transition at a critical shear rate. The model is used to study the rate of desorption of individual chains grafted via compact end-stickers and insoluble polymer blocks. In both cases, there is a strong increase in desorption at the swelling transition. For the case of end-sticker grafting, we find the desorption rate $\cal{R}$ obeys $\cal{R}$ $\sim \dot \gamma^{3}$ for large shear rates; while in the case of diblock grafting, we find that the barrier height to desorption is a strong function of shear rate, leading to an exponentially enhanced desorption rate for large $\dot\gamma$: $\cal{R}$ $\sim {\rm e}^{\dot\gamma\tau_0}$.



© Les Editions de Physique 1996